日本福利片在线观看-日本肥妇-日本动漫看片黄a免费看-日本动漫的18涩涩视频-成人久久免费视频-成人久久伊人精品伊人

鄭州變頻器維修銷(xiāo)售廠家

公司logo

16年專(zhuān)注于河南變頻器維修銷(xiāo)售
變頻器行業(yè)誠(chéng)信企業(yè)、質(zhì)量、服務(wù)

全國(guó)咨詢(xún)熱線(xiàn)155-155-98858

技術(shù)資訊

技術(shù)資訊

SEW變頻器MOVITRAC-31C系列故障代碼

發(fā)布時(shí)間:2019-08-02 15:34:55來(lái)源:

錯(cuò)誤代碼 型號(hào) 品牌 錯(cuò)誤類(lèi)型 錯(cuò)誤原因 解決辦法
1 MOVITRAC-31C SEW Overcurrent Short circuit/earth fault at the output.Motor too large.Faulty output stage. Remove short-circuit.Connect smaller motor.If fault can still not be reset,contact SEW service.
2 MOVITRAC-31C SEW DC link voltage DC link voltage too high. Increase deceleration ramps.
3 MOVITRAC-31C SEW Brake chopper Regenerative power too highBraking resistor circuit interruptedShort-circuit in the brakingresistor circuitBraking resistance value too highFaulty brake chopper Increase deceleration ramps.Check connecting leads of thebraking resistor.Check technical data of thebraking resistor.Exchange MOVITRAC® 31C
5 MOVITRAC-31C SEW Regenerativeoverload With active regen. n monit. (P520/P522)and speed control (P770):faulty encoder signalswrong number of pole pairs (P324/P344)value of increments (P773) not correct Check encoder.Check encoder connection.Set number of pole pairs correctly.Set value of increments correctly.
4 MOVITRAC-31C SEW Cont. overload ´t utilization too high (> 125(%)). Reduce load.
6 MOVITRAC-31C SEW Overtemperature Thermal overload of the inverter. Reduce load and / or ensure adequatecooling.
7 MOVITRAC-31C SEW Phase failure With active mains volt. monitor.(P530)Phase missing at TL. X1:1/2/3. Check mains supply.
10 MOVITRAC-31C SEW Direction ofrotation Only with active speed control (P770):Encoder tracks A/A and B/B areswapped in pairs.Motor rotates in opposite direction.Regen. overload (i.e. with sagging hoist)because of excessive load or BOOSTsetting too low (P321/P341). Check encoder connection.Exchanging two motor phases.Reduce load or increase BOOST.
11 MOVITRAC-31C SEW Speeddetection Only with active speed control (P770):Faulty encoder connection.FEN31C/FPI31C option not installed. Check encoder connection.Insert correct option(FEN31C or FPI31C).
12 MOVITRAC-31C SEW Mot. overload With active n monit. (P510/P512)and speed control (P770):faulty encoder signalswrong number of pole pairs (P324/P344)value of increments (P773) not correct Check encoder.Check encoder connection.Set number of pole pairs correctly.Set value of increments correctly.
13 MOVITRAC-31C SEW Startingconditions With active hoist function (P710/P712):Current too low during the premagnetizationphase:Motor rated power selected too smallin relation to the inverter rated power.Cross-section of the motor leads toosmall. Check startup data and carryout new startup if necessary.Check inverter-motor connection.Check cross-section of the motorleads and increase if necessary.
14 MOVITRAC-31C SEW Output open With active hoist function (P710/P712):Two or all output phases interrupted.Motor rated power selected too smallin relation to the inverter rated power. Check inverter-motor connection.Check startup data and carryout new startup if necessary.
17 MOVITRAC-31C SEW Stack overflow Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
18 MOVITRAC-31C SEW Stack underflow Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
19 MOVITRAC-31C SEW NMI trap Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
20 MOVITRAC-31C SEW Undefinedopcode Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
21 MOVITRAC-31C SEW Protected instr. Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
22 MOVITRAC-31C SEW Word op.access Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
23 MOVITRAC-31C SEW nstruct. access Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly,
24 MOVITRAC-31C SEW Ext. bus access Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
25 MOVITRAC-31C SEW EEPROM Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
26 MOVITRAC-31C SEW No connection Inverter electronics faulty.Possible cause: EMC effect. The notes for EMC compliant installationmust be observed.The reset for error 25 consists ofseveral steps:1. Factory setting (P830 = YES)2. Re-set matched parameters3. Carry out resetIf fault occurs repeatedly, contactSEW service.
27 MOVITRAC-31C SEW Ext. terminal External fault signal has appeared at a programmableinput Eliminate the cause of the fault. Reprogramthe terminal, if necessary
28 MOVITRAC-31C SEW FaultINTERBUS FFI31C and control mode (P841) = Fieldbus:Faulty monitoring signal. Check Fieldbus connection.
32 MOVITRAC-31C SEW Copying Only when copying the parameters (P820):Break or interference in PC or FBG31Cconnection. Check connection between inverter andPC. Remove FBG31C keypad and plugagain.
33 MOVITRAC-31C SEW Master-slave Connection master-slave is interrupted.0V5 connection (RS-485) missingMaster or slave defined incorrectlyin P880. Check master-slave connection.0V5-establish connection betweenmaster and slaveSet P880 correctly.
34 MOVITRAC-31C SEW Fieldbustimeout No communication between master andslave within the specified time of theresponse monitoring. Check communication routine of themaster.Increase fieldbus timeout time (P571)/deactivate monitoring.
35 MOVITRAC-31C SEW ConnectionEncoder-FRS Encoder connection faulty.Power supply of the encoder faulty. Check encoder connection.Check power supply of the encoder.
36 MOVITRAC-31C SEW ConnectionMaster-slave Only with FRS and cable break master-slave(P557) = YES:Setpoint connection of slave (TL. 98-101)is disrupted.Master Speed 0 ® slave FRS CTRLis disrupted.Slave FRS CTRL input not assigned.Master Speed 0 output not assigned.No master inverter available.Encoder < 512 pulses per revolution used. Check installation.Check programming of the binaryinputs and binary outputs.Check if encoder type is correct.
37 MOVITRAC-31C SEW FRS RAM fault Internal fault. If fault occurs repeatedly, contactSEW service.
38 MOVITRAC-31C SEW FRS processdata fault Fault on interface between inverter andFRS. If fault occurs repeatedly, contactSEW service.
39 MOVITRAC-31C SEW FRS parameterdata fault Invalid value for FRS parameters (P55_). Check parameter settings.
41 MOVITRAC-31C SEW FRS lag fault Polarity of the encoder not set correctly.Acceleration ramps too short.P-gain of the positioningcontroller too smallSpeed controller not set property.Value for lag error tolerance too small Change polarity of encoder.Increase ramps.Increase P-gain.Select new parameters forspeed controller.Increase lag error tolerance (P551).Check wiring of encoder, motor andmains phases.Check if mechanical system is sluggishor whether drive hit an obstacle.
43 MOVITRAC-31C SEW Faultbinary output Load on TL. X3:61 > 150 mA.Load on the otherbinary outputs > 50 mAShort circuit on binary output.Capacitive load on binary output. Check installation of the binary outputs.

SEW變頻器維修MOVITRAC-31C系列  15515598858  0371-56700815

用手機(jī)看
SEW變頻器MOVITRAC-31C系列故障代碼

拍下二維碼,信息隨身看

試試用手機(jī)掃一掃,
在你手機(jī)上繼續(xù)觀看此頁(yè)面。

主站蜘蛛池模板: 色妞www精品视频免费看| 大黄毛片| 国产黄色视屏| 成人毛片免费观看| 中国嫩模一级毛片| 色吊丝最新网址| 亚洲天堂久久| 美女黄频免费看| 亚洲视频一区网站| 四虎影院永久在线| 免费看毛片的网址| 国产永久免费观看视频软件| 四虎影院黄色| 91好色视频| 国产精品系列在线一区| 亚洲伊人激情| 91久久偷偷做嫩草影院免费| 久久新网址| 性毛片| 国产91亚洲精品| 毛片免费全部完整播放| 国产网站91| 不卡一区二区三区四区| 四虎永久免费在线| 片在线观看| 国产精品成人影院| 日韩城人免费| 中文字幕日韩一区| 国产永久精品| 黄色免费在线观看网站| 欧美日韩综合网在线观看| 午夜手机视频| 91精品国产一区| 99久热只有精品视频免费看| 在线视频精品视频| 天天摸天天舔天天操| 国产欧美精品亚洲桃花岛| 天堂网中文字幕| 久久综合日韩亚洲精品色| 一区精品视频| 一级aaaaa毛片免费视频|